All In Data Center · Knowledge Base

Technical Terminology

The working vocabulary of the data-center industry — facility, power, cooling, IT & network, CSA, MEP, commissioning, sustainability, operations and project controls, defined for engineers, operators and builders.

0 terms 0 categories 0 subcategories
0 terms
0 results
Sort

Network & Connectivity

1.6T Ethernet

1.6T Ethernet is a 1.6 terabit-per-second Ethernet interface being defined in the IEEE P802.3dj project alongside 800G, built on higher-rate 200G-per-lane signalling. Targeted at next-generation AI…

Data Center Network ArchitectureRead →

IT & Compute Infrastructure

100 kW Rack

A 100 kW Rack is a cabinet provisioned to supply and cool roughly 100 kilowatts of IT load, a density driven by dense GPU and AI…

AI & HPC InfrastructureRead →

IT & Compute Infrastructure

19-Inch Rack

A 19-Inch Rack is the standard equipment rack whose mounting rails are spaced so that installed gear presents a 19-inch (482.6 mm) front panel width, with…

Servers & RacksRead →

Sustainability & Metrics

24/7 Carbon-Free Energy

24/7 Carbon-Free Energy (24/7 CFE) is a procurement goal in which every hour of a data center's electricity consumption is matched with carbon-free generation on the…

Energy & CarbonRead →

Resilience & Availability

2N

2N is a fully redundant configuration that duplicates the entire system, providing two complete, independent capacity sets where either alone can carry the full load. This…

Redundancy TopologiesRead →

Resilience & Availability

2N+1

2N+1 is a redundancy configuration that provides two full, independent systems (2N) plus one additional spare unit, so redundancy is preserved even during maintenance of one…

Redundancy TopologiesRead →

IT & Compute Infrastructure

30 kW Rack

A 30 kW Rack is a cabinet provisioned to supply and cool about 30 kilowatts of IT load, a density associated with high-performance and early AI…

AI & HPC InfrastructureRead →

Resilience & Availability

3N/2

3N/2 (also called distributed redundancy) is a topology that uses three capacity units to support two units' worth of load, spreading the load and reserve across…

Redundancy TopologiesRead →

Network & Connectivity

400G ZR

400G ZR is a coherent pluggable optics specification, defined by the Optical Internetworking Forum, that carries a 400 Gigabit Ethernet signal directly over DWDM fiber for…

Structured CablingRead →

Power Infrastructure

48V DC Distribution

48-volt DC distribution delivers direct current at 48 volts from a central rectifier or power shelf to servers, eliminating repeated AC-DC conversions and reducing current and…

Power DistributionRead →

Design & Engineering

4D BIM

4D BIM links the 3D model to the construction programme, adding time as a fourth dimension so the build sequence can be simulated and visualised against…

BIM, Revit & Digital DeliveryRead →

Design & Engineering

5D BIM

5D BIM adds cost information to the time-linked model, associating quantities and prices with model elements so budgets and cash flow update as the design and…

BIM, Revit & Digital DeliveryRead →

Network & Connectivity

800G Ethernet

800G Ethernet is an 800 gigabit-per-second Ethernet interface standardised in IEEE 802.3df, typically implemented as eight 100G electrical lanes in QSFP-DD or OSFP modules. It is…

Data Center Network ArchitectureRead →

Network & Connectivity

95th Percentile Billing

95th Percentile Billing is a method of charging for bandwidth in which usage is sampled at regular intervals over the month, the top five percent of…

Internet & InterconnectionRead →

Power Infrastructure

A-Side and B-Side Power

A-Side and B-Side Power refers to two independent, redundant power distribution paths (A and B) feeding the same equipment from separate sources, so that failure or…

Power DistributionRead →

Network & Connectivity

A-Side Demarc

An A-Side Demarc is the first of two independent demarcation points provided for a diversely routed, redundant service, terminating one of the two physical paths into…

Internet & InterconnectionRead →

Resilience & Availability

A/B Power Path

An A/B Power Path is a design that supplies IT equipment from two independent electrical distribution paths, the A side and the B side, each with…

Redundancy TopologiesRead →

Fire & Life Safety

Abort Switch

An Abort Switch is a manually operated control that, when held or activated during the pre-discharge countdown, delays or halts the release of a fire-suppression agent.…

Fire SuppressionRead →

Cooling & Environmental Control

Absolute Humidity

Absolute Humidity is the actual mass of water vapor present in a given volume or mass of air, expressed for example in grams per kilogram of…

Environmental MonitoringRead →

IT & Compute Infrastructure

Accelerator

An Accelerator is specialized hardware that performs certain computations far faster or more efficiently than a general-purpose CPU, such as a GPU, TPU, FPGA or custom…

AI & HPC InfrastructureRead →

Security & Compliance

Access Control List

An Access Control List (ACL) is a defined set of rules specifying which individuals or systems are permitted or denied access to a particular resource, area,…

Physical SecurityRead →

MEP - Electrical Systems

Access Control System

An Access Control System is an electronic security system that manages and records who may enter defined areas, using credentials such as cards, PIN codes or…

ELV, ICT & Security SystemsRead →

Architecture & Building Envelope

Access Hatch

An Access Hatch is a hinged or removable panel set into a floor, ceiling, roof or wall that provides entry to a concealed space such as…

Doors, Openings & Security InterfacesRead →

Colocation & Cloud Services

Access Request

An Access Request is the formal procedure by which a colocation customer authorizes named individuals to enter the facility or their secured space, specifying identity, escort…

Colocation ProductsRead →

Colocation & Cloud Services

Access SLA

An Access SLA is a service level commitment covering how quickly and reliably a customer can gain physical entry to their equipment or space, including 24/7…

Service LevelsRead →

Architecture & Building Envelope

Access-Controlled Opening

An Access-Controlled Opening is a door or portal whose use is governed by an electronic access-control system, combining a reader, electric lock, position switch, request-to-exit device…

Doors, Openings & Security InterfacesRead →

Architecture & Building Envelope

Acoustic Door

An Acoustic Door is a door assembly designed to attenuate sound transmission, achieving a rated sound reduction index (Rw) through a heavy leaf, perimeter seals and…

Doors, Openings & Security InterfacesRead →

Architecture & Building Envelope

Acoustic Louver

An Acoustic Louver is a louver with sound-absorbing blades that permits airflow while reducing the noise passing through a ventilation opening. In data centers acoustic louvers…

Envelope, Roofing & WeatherproofingRead →

Architecture & Building Envelope

Acoustic Partition

An Acoustic Partition is an internal wall designed to attenuate sound transmission between spaces, achieving a specified sound reduction rating through mass, isolation and sealing. In…

Architectural Planning & Code ComplianceRead →

Power Infrastructure

Active Harmonic Filter

An active harmonic filter is a power-electronic device that measures load current harmonics and injects an equal, opposite current to cancel them, keeping the supply current…

Power DistributionRead →

Network & Connectivity

Active Optical Cable

An Active Optical Cable (AOC) is a fixed assembly with optical transceivers permanently attached to both ends of a fiber, presenting the same electrical interface as…

Structured CablingRead →

Cooling & Environmental Control

Active Rear-Door Heat Exchanger

An Active Rear-Door Heat Exchanger is a chilled-water coil mounted on the back of a rack with integral fans that draw server exhaust through the coil,…

Liquid CoolingRead →

Resilience & Availability

Active-Active Site

An Active-Active Site configuration runs two or more sites simultaneously, each handling live production traffic and sharing the workload while backing one another up. Because both…

Business ContinuityRead →

Resilience & Availability

Active-Passive Site

An Active-Passive Site configuration runs production at a primary site while a secondary standby site remains idle or lightly loaded, ready to take over on failover.…

Business ContinuityRead →

Planning, Scheduling & Project Controls

Activity

An Activity is the fundamental unit of work in a schedule, a discrete task with a defined duration, logic links to other activities, and often assigned…

Primavera P6 & Scheduling StructureRead →

Planning, Scheduling & Project Controls

Activity Code

An Activity Code is a user-defined attribute assigned to activities in Primavera P6 to classify, filter, group and report them by dimensions such as area, phase,…

Primavera P6 & Scheduling StructureRead →

Planning, Scheduling & Project Controls

Activity ID

An Activity ID is the unique alphanumeric identifier assigned to each activity in a schedule, used to reference, sort and track it consistently across updates, reports…

Primavera P6 & Scheduling StructureRead →

Planning, Scheduling & Project Controls

Actual Cost

Actual Cost (AC) is the total cost genuinely incurred for the work completed to date, drawn from cost accounts and invoices. Also called Actual Cost of…

Progress, Earned Value & ReportingRead →

Planning, Scheduling & Project Controls

Acumen Fuse

Acumen Fuse is a schedule and project analytics tool by Deltek that diagnoses schedule quality, logic issues and risk drivers, running metrics such as the DCMA…

Planning Tools & Risk AnalyticsRead →

Sustainability & Metrics

Additionality

Additionality is the principle that an emissions reduction or clean-energy purchase only counts if it would not have happened without the buyer's intervention. It is central…

Energy & CarbonRead →

Fire & Life Safety

Addressable Detector

An Addressable Detector is a fire detector with a unique electronic address on a signalling loop, allowing the control panel to identify the exact device and…

Fire DetectionRead →

Cooling & Environmental Control

Adiabatic Cooler

An Adiabatic Cooler is a dry cooler enhanced with evaporative pre-cooling that wets or humidifies the incoming air to lower its temperature toward the wet-bulb during…

Heat RejectionRead →

Architecture & Building Envelope

Adjacency Matrix

An Adjacency Matrix is a planning tool, in grid form, that records how strongly each space should be located near or apart from every other space.…

Architectural Planning & Code ComplianceRead →

Fire & Life Safety

Agent Concentration

Agent Concentration is the proportion of suppression agent, by volume, achieved in a protected space, which must reach the design level needed to extinguish fire while…

Fire SuppressionRead →

Data Center Facility & Site

AI Factory

An AI Factory is a data center or facility purpose-built to train and run artificial-intelligence workloads at scale, densely packed with GPU or accelerator clusters. Characterized…

Campus & Edge FacilitiesRead →

IT & Compute Infrastructure

AI Rack

An AI Rack is a cabinet configured for artificial-intelligence workloads, densely populated with GPU or accelerator servers, high-speed networking and often integrated liquid cooling and high-capacity…

AI & HPC InfrastructureRead →

IT & Compute Infrastructure

AI Training Cluster

An AI Training Cluster is a large group of interconnected accelerator servers dedicated to training machine-learning models on massive datasets. In data centers it demands extreme…

AI & HPC InfrastructureRead →

Operations & DCIM

AIOps

AIOps (Artificial Intelligence for IT Operations) is the application of machine learning and analytics to the streams of telemetry, logs and events a data center generates,…

Monitoring & Control SystemsRead →

Architecture & Building Envelope

Air Barrier

An Air Barrier is a continuous system of materials and seals that stops uncontrolled air leakage through the building envelope while still allowing designed ventilation. It…

Envelope, Roofing & WeatherproofingRead →

Power Infrastructure

Air Circuit Breaker

An Air Circuit Breaker (ACB) is a low-voltage breaker that interrupts high currents in air, using arc chutes to stretch and cool the arc, and is…

Power DistributionRead →

Security & Compliance

Air Gap

An air gap is a security measure that physically or logically isolates a system or network so it has no active connection to untrusted networks such…

Cybersecurity & Zero TrustRead →

MEP - Mechanical Systems

Air Handling Unit

An Air Handling Unit (AHU) is a packaged assembly of fans, filters, heating or cooling coils, dampers and controls that conditions and moves air through ductwork…

Air Systems & VentilationRead →

MEP - Mechanical Systems

Air Separator

An Air Separator is a device that removes entrained and dissolved air from circulating water, releasing it through an automatic vent. Eliminating air prevents corrosion, noise,…

HVAC Plant & DistributionRead →

Cooling & Environmental Control

Air-Cooled Chiller

An Air-Cooled Chiller is a chiller that rejects heat directly to the atmosphere through integral condenser coils and fans, requiring no cooling tower or condenser-water system.…

Heat RejectionRead →

Cooling & Environmental Control

Air-Side Economizer

An Air-Side Economizer uses filtered outside air to cool a data center directly when ambient conditions are favorable, reducing or eliminating mechanical refrigeration. Direct systems introduce…

Air CoolingRead →

Cooling & Environmental Control

Airflow Management

Airflow Management is the discipline of controlling how cooling air moves through a data center so that cold supply air reaches equipment intakes and hot exhaust…

Air CoolingRead →

Cooling & Environmental Control

Airflow Sensor

An Airflow Sensor is a device that measures the velocity or volumetric rate of air movement, often using thermal, vane or pressure-based principles. In data centers…

Environmental MonitoringRead →

Architecture & Building Envelope

Airlock

An Airlock is a small chamber bounded by two interlocked doors that are not opened at the same time, maintaining a pressure or contamination barrier between…

Doors, Openings & Security InterfacesRead →

MEP - Plumbing & Fire Protection

Alarm Check Valve

An Alarm Check Valve is a one-way valve installed on a wet-pipe sprinkler riser that permits water to flow toward the sprinklers while preventing backflow, and…

Fire Protection SystemsRead →

Operations & DCIM

Alarm Flood

An Alarm Flood is a burst of alarms arriving faster than operators can read and act on them, typically triggered by a single upstream fault cascading…

Monitoring & Control SystemsRead →

Full index — all 1,650 terms

Every term in the DC Encyclopedia, A to Z. Each entry is sourced and dated.

A90

A-Side and B-Side PowerA-Side DemarcA/B Power PathAbort SwitchAbsolute HumidityAcceleratorAccess Control ListAccess Control SystemAccess HatchAccess RequestAccess SLAAccess-Controlled OpeningAcoustic DoorAcoustic LouverAcoustic PartitionActive Harmonic FilterActive Optical CableActive Rear-Door Heat ExchangerActive-Active SiteActive-Passive SiteActivityActivity CodeActivity IDActual CostAcumen FuseAdditionalityAddressable DetectorAdiabatic CoolerAdjacency MatrixAgent ConcentrationAI FactoryAI RackAI Training ClusterAIOpsAir BarrierAir Circuit BreakerAir GapAir Handling UnitAir SeparatorAir-Cooled ChillerAir-Side EconomizerAirflow ManagementAirflow SensorAirlockAlarm Check ValveAlarm FloodAlarm RationalizationAlarm VerificationAlarm ZoneAll-Flash ArrayAnchor Bolt TemplateAngled Physical Contact ConnectorAnnualized PUEANSI/TIA-942Anti-PassbackAnti-TailgatingAnycast GatewayApproach TemperatureArc Flash StudyArc-Resistant SwitchgearArchitectural LouverAs-Built DrawingASHRAE 90.4ASHRAE Allowable EnvelopeASHRAE Liquid Cooling ClassesASHRAE Recommended EnvelopeASHRAE TC 9.9Asphalt Wearing CourseAspirating Smoke DetectionAssembly PointAsset LifecycleAsset TagAsta PowerprojectATS PanelAttenuation TankAudit EvidenceAudit TrailAutoCAD DrawingAutodesk Construction CloudAutomatic Number Plate RecognitionAutomatic Transfer SchemeAutomatic Transfer SwitchAutomatic Voltage RegulatorAutonomous System NumberAutonomy TimeAvailabilityAvailability ClassAvailability CommitmentAvailability ZoneAvoided Emissions

C191

C-RateCabinetCabinet ColocationCabinet PowerCable DeratingCable LabelingCable Landing StationCable Management ArmCable PathwayCable PenetrationCable ScheduleCable TrayCAD StandardsCageCalendarCalibrated Vent TileCalifornia Bearing Ratio (CBR)Campus Expansion ReserveCampus Master PlanCapacity ForecastCapacity ManagementCapacity PlanningCARCarbon AccountingCarbon CreditCarbon IntensityCarbon NeutralCarbon OffsetCarbon-Free EnergyCard Reader Rough-InCarrier DiversityCarrier HotelCarrier-Neutral ColocationCarrier-Neutral FacilityCast-In-Situ ConcreteCat6A CablingCatch BasinCatcher SystemCause and Effect TestCBSCCTVCCTV SystemCDECDPCement StabilizationCentral ModelCephCERCFCIChain of CustodyChange ControlChange ManagementChange OrderChaos EngineeringCheckpointingChemical Dosing PotChemical DrainChilled Water LoopChilled Water PlantChillerChiller TurndownClash DetectionClash ReportClean Agent ReleaseClean Agent SystemCleanable FinishCleanoutClear HeightClimate Neutral Data Centre PactCLOS FabricClosed-Circuit Cooling TowerClosed-Loop CoolingCloud AdjacencyCloud Availability ZoneCloud ExchangeCloud Landing ZoneCloud On-RampCloud RegionCloud RepatriationCMDBCMMSCo-Packaged OpticsCOBieCoefficient of PerformanceCoherent OpticsCold AisleCold Aisle ContainmentCold PlateCold ShellCold SiteCold Water Storage TankCollective CommunicationColocation AgreementColocation CampusColumn GridCommissioned CapacityCommissioning AgentCommissioning Issue LogCommissioning PlanCommissioning ReportCommissioning ScriptCommon CriteriaCommon Data EnvironmentCommon Mode FailureCompaction TestCompliance MatrixComposable InfrastructureComposite BeamComputational Fluid DynamicsCompute Express LinkComputer RoomComputer Room Air ConditionerComputer Room Air HandlerConcept DesignConcrete Cube TestConcrete Mix DesignConcrete PavementConcurrent DelayConcurrent Maintainability DemonstrationConcurrently MaintainableCondensate DrainCondenser Water LoopCondenser Water SystemCondition MonitoringConstraint DensityConstructed Facility CertificationConstruction Management at RiskConstruction ManagerConstruction RiskConstruction SequenceContainer PlatformContainerized Data CenterContainment LeakageContainment SegregationContent GovernanceContinuous CoolingContracted PowerContractor-Furnished EquipmentControl Loop TuningControl ObjectiveControl OwnerControl PanelControl PhilosophyControlled DocumentCoolant ChemistryCoolant Distribution UnitCoolant Filtration SkidCoolant ManifoldCooling CapacityCooling CoilCooling Efficiency RatioCooling TowerCooling Tower RangeCoordination DrawingCOPCopper BackboneCore and ShellCore WallCorrective Action RequestCorrective MaintenanceCost Performance IndexCost Plus ContractCost VarianceCost-Loaded ScheduleCounterflashingCRACCRAHCrane PlanCrash BarCrash-Rated BollardCrime Prevention Through Environmental DesignCrisis ManagementCritical LoadCritical PathCritical Path MethodCross-ConnectCross-Connect Delivery SLACross-Connect FeeCross-Zoned DetectionCSA ContractorCSA STARCSRDCUECurrent BaselineCurtailmentCustomer EscalationCustomer PortalCut and FillCxACycles of ConcentrationCylinder Bank

D116

Damper ActuatorDangling ActivityDark FiberData Center as a ServiceData Center CampusData Center InterconnectData HallData ParallelismData Processing UnitDay TankDay Tank ControlsDCePDCiEDCIMDCMA 14-Point AssessmentDDC ControllerDDoS ProtectionDead LoadDecommissioningDecouplerDedicated HallDeduplicationDefense in DepthDefinition StandardDeflection LimitDeliverable PowerDelta TDelta-Conversion UPSDeluge SystemDeluge ValveDemand FactorDemand FlexibilityDemand ResponseDemarcation PointDepth of DischargeDesign BriefDesign CapacityDesign CertificationDesign Change NoticeDesign Coordination WorkshopDesign Criteria MatrixDesign DevelopmentDesign for Manufacture and Assembly (DfMA)Design FreezeDesign NarrativeDesign PUEDesign ReviewDesign RiskDesign-Bid-BuildDesign-BuildDetector MaintenanceDetector SensitivityDew PointDewateringDGX SuperPODDGX SystemDielectric FluidDiesel Exhaust FluidDiesel Fire PumpDiesel GeneratorDiesel Rotary UPSDifferential PressureDifferential Pressure SensorDiffuserDigital Operational Resilience ActDigital TwinDirect Attach Copper CableDirect Cloud ConnectDirect Evaporative CoolingDirect Expansion CoolingDirect Liquid CoolingDirect-to-Chip CoolingDirt SeparatorDisaggregated InfrastructureDisaster RecoveryDisaster Recovery RepositoryDischarge NozzleDisproportionate CollapseDistributed CloudDistributed RedundancyDistrict Heat NetworkDistrict Heating ExportDiverse Utility FeedDiversity FactorDock LevellerDomestic Hot Water SystemDomestic Water SystemDoor InterlockDoor Position SwitchDoor ScheduleDouble Interlock SystemDouble-Conversion UPSDouble-Interlock Pre-ActionDowntime BudgetDrawing RegisterDrift EliminatorDrift LimitDrip TrayDriven PileDriving PathDry CoolerDry Pipe SystemDry-Type TransformerDual-Corded LoadDuct BankDuct Pressure ClassDuct Smoke DetectorDucted CabinetDuctwork Leakage TestDuress AlarmDWDMDWG FileDXF FileDynamic BlockDynamic CommissioningDynamic Load

P130

P50 DateP6 EPPMP6 ProfessionalP80 DatePad FootingPanelboardPanic HardwarePaper SpaceParallel File SystemPartial CabinetPartial PUEPassive Rear-Door Heat ExchangerPatch CordPatch ManagementPatch PanelPatch Panel ServicePatch Panel TerminationPavement Build-UpPCI DSSPeak ShavingPenetration DrawingPenetration TestingPerformance BondPerformance Measurement BaselinePerimeter FencePerimeter Intrusion Detection SystemPermit to WorkPermitting RiskPhased Build-OutPhotoelectric Smoke DetectorPhysical Access Control SystemPhysical Security Information ManagementPID LoopPile CapPile FoundationPing Power PipePipe PenetrationPipeline ParallelismPlanned MaintenancePlanned ValuePlantroom DrainagePlate Heat ExchangerPlate Load TestPlatform as a ServicePlaybookPlot StylePodPoint Cloud SurveyPoint LoadPoint of Common CouplingPoint of PresencePoint-to-Point TestPoints ListPolicy ControlPort CapacityPortable Fire ExtinguisherPortal FramePost-Incident ReviewPost-Tensioned SlabPower AvailabilityPower Availability SLAPower CapacityPower CappingPower Cord LockingPower DensityPower Distribution UnitPower Factor CorrectionPower MeterPower Monitoring MeterPower Panel SchedulePower Purchase AgreementPower QualityPower ShelfPower-Based PricingPowered LandPowered ShellPractical CompletionPre-Action SprinklerPre-Action ValvePre-AlarmPre-CommissioningPre-Functional ChecklistPrecast Concrete PanelPreconstruction ServicesPredictive MaintenancePrefabricated Modular Data CenterPrefabricated Plant ModulePressure Reducing ValvePressure TransmitterPressurization UnitPreventive MaintenancePrimary Injection TestPrimary PumpPrimary Steel FramePrimavera P6Prime ContractorPrime Power RatingPrinciple of Least PrivilegePriority Flow ControlPrivate CloudPrivate PeeringPrivate SuitePrivileged Access ManagementProblem ManagementProcedure ControlProctor TestProcurement Lead TimeProcurement PackageProcurement ScheduleProject CalendarProject ParameterPropylene Glycol SolutionProtection ClassProtection Coordination StudyProvisional SumPsychrometricsPublic Address SystemPublic CloudPublic Key InfrastructurePublic PeeringPUEPUE Measurement CategoryPull-the-Plug TestPump SkidPumped Refrigerant EconomizerPumped Two-Phase CoolingPunch ListPunch List CloseoutPunch WalkPurchase Order

R107

Rack DensityRack ElevationRack GroundingRack Inlet TemperatureRack PDURack Power WhipRack ReservationRack ServerRack UnitRaft FoundationRail-Optimized NetworkRail-Optimized TopologyRainscreen CladdingRainwater HarvestingRaised FloorRAMS (Risk Assessment and Method Statement)Rated-1Rated-2Rated-3Rated-4RDMARDMA over Converged EthernetReactive Load BankReactive PowerReady-for-ServiceRear Door Heat ExchangerRebarRecirculationReclaimed WaterRecovery Point ObjectiveRecovery SiteRecovery Time ObjectiveRed TeamRedfishRedline DrawingReduced Pressure Zone AssemblyRedundant Capacity ComponentREFReference DesignRefrigerant CondenserRefuge AreaRegional HubRegisterReinforcement ScheduleRelated TermRelationshipRelative HumidityReliability DemonstrationReliability-Centered MaintenanceRelief AirRemote HandsRemote Hands FeeRemote Hands SLARemote Power PanelRemote RadiatorRenewable Energy CertificateRenewable Energy FactorReplicationRequest for InspectionResilience ScenarioResistive Load BankResolution TimeResource CalendarResource LevelingResponse Spectrum AnalysisResponse Time SLARetail ColocationRetaining WallRetentionRetro-CommissioningReturn AirReturn Air DuctRevenue MeterReverse Osmosis SystemRevision CloudRevit FamilyRevit ModelRFIRide-Through TimeRing Main UnitRisk AppetiteRisk AssessmentRisk RegisterRisk Treatment PlanRoad GullyROADMRoCERock ExcavationRole-Based Access ControlRoller ShutterRoof CurbRoof DeckRoof DrainRoof Live LoadRoof PenetrationRoof TrussRoof WalkwayRoom Data SheetRoom Finish ScheduleRoom Integrity Fan TestRoom Integrity TestRoom-Based CoolingRoot Cause AnalysisRound SheetRound-Trip EfficiencyRoute ServerRunbook

S179

S-CurveSafran RiskSanitary DrainageSBTiSCADAScalable BlockScale-Out ArchitectureScale-Up ArchitectureSchedule AuditorSchedule Health CheckSchedule Performance IndexSchedule VarianceSchematic DesignScope 1 EmissionsScope 2 EmissionsScope 3 EmissionsScupperSecond FixSecond Line SupportSecondary Cooling LoopSecondary PumpSecondary SteelworkSecure Remote AccessSecurity DoorSecurity EscortSecurity GatehouseSecurity Information and Event ManagementSecurity Operations CenterSecurity Orchestration Automation and ResponseSecurity RiskSecurity VestibuleSecurity ZoneSeismic BracingSeismic LoadSeismic RiskSelective Catalytic ReductionSelective CoordinationSelf-Contained Data CenterSensible CoolingSensor CalibrationSensor DriftSEO SlugSequence of OperationSequence of OperationsSequence of Operations TestServerServer SledService CreditService Level AgreementService Level IndicatorService Level ObjectiveService RestorationService YardSetpointSettlement-Free PeeringSewage EjectorShallow FoundationShared FateShared ParameterSHARPShear Stud ConnectorShear WallSheet PilingSheet SetShift HandoverShop DrawingShoringShort Circuit StudyShort-Circuit RatingSilicon PhotonicsSingle Line DiagramSingle Point of FailureSingle-Mode FiberSingle-Phase ImmersionSingle-Ply Roofing MembraneSingle-Tenant Data CenterSite Acceptance TestSite GradingSite Logistics PlanSite MobilizationSite Test ReportSite WUESkid-Mounted Data CenterSlab-on-Grade Data HallSleeveSleeving DrawingSlump TestSlurmSmall Modular ReactorSmart HandsSmartNICSmoke CompartmentSmoke ControlSmoke CurtainSmoke DamperSmoke Extract DuctSmoke Sampling PipeSmoke VentSnag ListSnaggingSnapshotSNMPSnow LoadSOC 2SOC 2 Type IISoftware-Defined StorageSoil Bearing CapacitySoil StabilizationSolid-State TransformerSONiCSOPSource WUESovereign CloudSpace CapacitySpace ProgramSpanning Tree ProtocolSpares StrategySpine SwitchSpot Smoke DetectorSprinkler HeadSprinkler RiserSprinkler ZoneSR-IOVSSAE 18Staging RoomStairwell PressurizationStandby GeneratorStandpipe SystemStart-to-FinishStart-to-StartState of ChargeStatement of ApplicabilityStatic Bypass SwitchStatic CommissioningStatic Transfer SwitchStatic UPSSteel Door SetSteel ErectionStep-Down TransformerStorage Area NetworkStorage RoomStorage-Class MemoryStormwater ManholeStrainerStranded CapacityStranded PowerStrip FootingStructural BayStructural Expansion JointStructured CablingStructured Cabling DesignSTS CabinetSubcontractorSubmain CableSubmarine CableSubmittal RegisterSubsea Data CenterSubstantial CompletionSump PumpSupercapacitor Energy StorageSuperimposed Dead LoadSuperspineSupplementary BaselineSupply AirSupply Air DuctSupply Air Temperature SetpointSupply Chain SecuritySupply Temperature ResetSuppression Release PanelSurge Protection DeviceSurveillance InspectionSwitchboardSwitched Rack PDUSwitchgearSwitchgear Line-UpSXMSynchro 4DSynonymSystems Manual